log splitter valve sticking

On one side of the valve there is a inch long bolt only way I know how to describe it with a ball in the end. If the ram does not return after removing the DuoCut blade.


Horizontal Vertical Log Splitter 37 Ton Log Splitter Wood Splitter Log Splitters

When repairing a damaged pump it is important to carefully analyze and address the rest of the hydraulic system.

. In this stage the pump produces about 400-900psi which is far less than its rated GPM. Remove the carriage from the log splitter. The Hydraulic Log Splitter Valve.

Common problems with AL-KO and similar Chinese generic log splitters the hydraulic valve spindle breaks on the end stopping the unit from working correctly. East Brady PA. I disassembled the valve completely to inspect it.

I have a Power Pro log splitter made by Brave Model HP-1226F. To fix this the bleed valve needs to be opened and the pressure plate needs to be cycled back and forth a few times. I just bought a sweet 22-ton Splitter at Tractor Supply the Husky model made by Speeco I believe.

Loosen the two rear lock nuts on the carriage arms and remove the two nuts in front of the crosspiece. These vibrations or shaking could be due to the log splitter being low in hydraulic oil. Its working but not correctly.

Up to 32 cash back The log splitters hydraulic control valve directs the hydraulic fluid flow to the hydraulic cylinder to extend and retract the piston and wedge. Jun 9 2016. The two-bolt mount pumps come in 22gpm and 28gpm sizes and have a 58 keyed shaft that can differ in length.

When the pump fails it will often send metal debris. Checking each potential common cause can help you identify the problem and rectify it with simple troubleshooting steps. Remove the air from the system to solve this problem and keep the bleed valve tightened enough.

1 Find the diagram. Its a Huskee 22 ton and the valve is sticking both ways. If fluid is leaking from your pump disassemble it and replace all seals.

And it simultaneously allows oil from the rod-end port of the cylinder to flow into. I am borrowing my neighbors 27-ton Troy-Bilt log splitter. The hydraulic directional valve controls the motion of the cylinder.

There will be input valves for the pressurized and un-pressurized hose connections and the diagram will show you which ones go on which side of the detent valve and in what order. This valve is the most prevalent valve used in the residential log splitter industry. Ive got a Briggs Model 130202- 3116 5 HP on a log splitter.

And now it started to stick going out and it will go out to the end and stall. If the hydraulic hoses are hooked up incorrectly then the valve wont be able to function properly. If the oil is found to be enough then the problem is due to the air mixed with liquid when opening the bleed valve and cycling pressure plate.

Joined May 14 2017. An automatic process is carried out for transition from the first stage to the second. First turn the log splitter over and close off the air vent remove the motor and pump 3 x 13mm headed bolts and 1 x support bolt.

It didnt work properly when brand new. I pulled the cap and found it contaminated with moisture and it was lubricated with a silver pastegrease. I have a Brave Log splitter and the last few weeks the detentspoil valve has become sticky after the I split a couple of hours.

The detent cover on the hydraulic valve controls the auto-return. Anyone ever rebuild a log splitter hydaulic valve. Contents show 12 Common Causes for a Slow Log Splitter and their Solutions.

Stuck Troubled Vintage Ads Community Album Photo Ad Archives. My new to me Countyline Speeco 25 ton splitter control valve detent mechanism was sticking operating erratically and adjusting didnt solve the problem. The hydraulic valve has seals around the actuator rod that can wear out and fail over time.

The ball like a ball bearing moves in and out if you push on it and the. If hydraulic fluid leaks from the valve body around the actuator rod replace the hydraulic valve in the log. Articles Tractor Registry Tip of the Day.

If the levels look correct when checking this could mean that there is air within the oil lines. The seals on these pumps wear over time and eventually can cause hydraulic fluid to leak out of the system. Sometimes a second attempt lets it auto-reverse the ram other times I have to hold it in place to prevent it from prematurely kicking back into neutral.

Works great but the actuation lever sticks in the up position so tightly that it rarely kicks back to neutral when the ram is all the way up and I end up leaping back to the splitter over log sections to manually flip it before the engine stalls or a hydralic hose blows. Read about gas log splitter. I have an old home made log splitter30 years never a lick of problemsIt has been sitting a couple of years it started like usualI worked it about 12 hour added about 1-12 quart of hydraulic fluid Sams Club AW 46 RO Hydraulic Oil finished my workThe next day I discovered the control flow valve was stuck and cannot move it also the pump is seized.

Return Detent on Log Splitter Valve in reply to wsmm 09-25-2013 111353 Hello WSMM. Then it ran fine for about 20 minutes and I. Log splitter valve sticking Sunday April 24 2022 Edit.

Log Splitter Kick-Off Valve Compact 6 For technical questions call. You need to check the amount of oil first. The spool shifted by the handle has 3 positions.

Find the diagram of the detent valve set up. Blockage in the Fan. This tutorial apply to the Energy control valve.

Also it is hard to trip the lever to get it to stop retracting. Place the log splitter back upright and try the splitter again if it produces the same noise then loosen the bolts a little from the end of the pump 13mm and try again. If the ram still does not return then contact the dealer on 0191 276 6553.

Pushed one way it shunts oil from the pump to the base port of the cylinder causing it to extend. Discussion Starter 1 Sep 1 2021. Fixing the auto-return on a hydraulic control valve usually is just a matter of tightening The bolt inside the detent cover assembly.

There are two common types of mounts used on log-splitters. When it retracts it pulls in tight and stalls the engine. If still your log splitter shuts off under load most likely your hydraulic pump is jammed or stuck in its high flowlow-pressure stage described as the first stage.

The four-bolt mount pumps generally come in 5gpm-16 gpm sizes and have a ½ keyed shaft about 1-12 long. Make sure the oil levels are correct and. There is a four-bolt mount and a two-bolt mount.

Works fine except and he warned me that the handle sometimes pops back to neutral when in reverse mode.


Spareparts For Bt Ls 44 Einhell Log Splitter


Log Splitter Maintenance Youtube


Spareparts For Hsp 51 Einhell Log Splitter


Performance Log Splitter Clearance 52 Off Espirituviajero Com


Iron And Oak 24 Ton Vertical Horizontal Log Splitter Bhvh2418gx


Spareparts For Hsp 41 1 Einhell Log Splitter


Countyline 40 Ton Log Splitter Kohler Command Pro Ch440 14hp Engine 126151999 At Tractor Supply Co


Boss Industrial 27 Ton Horizontal And Vertical Gas Log Splitter Costco


Brute 35 Ton 250cc Full Beam Gas Log Splitter At Menards


Spareparts For Hsp 41 Einhell Log Splitter


Black Max 15 Amp Electric Log Splitter Walmart Com


Log Splitter Valve And Accessories By Energy Manufacturing Company Inc


Image Result For Log Splitter Design Plans Wood Splitter Log Splitter Firewood Processor


Spareparts For Bt Ls 44 Einhell Log Splitter


How To Fix The Automatic Return On A Log Splitter Offgridmaker Com


Log Splitter 37 Ton Gas Powered Wood Splitter Honda Engine


Performance Built 27 Ton 208 Cu Cm Horizontal And Vertical Gas Log Splitter With Briggs Stratton Engine In The Hydraulic Gas Log Splitters Department At Lowes Com


Log Splitter Valve 20 Gpm 1 2 Work Ports Auto Return Detent


Log Splitter Valve 20 Gpm 1 2 Work Ports Auto Return Detent